advanced EECP S machine for coronary artery disease with all-in-one design easy installation and operation



advanced EECP S machine for coronary artery disease with all-in-one design easy installation and operation
EECP ?
- EECP stands for Enhanced External Counter Pulsation therapy.
- It’s an alternative method to relieve heart pain by creating new vessels(collaterals) in the heart by pushing blood into the heart.
- EECP helps grow new collaterals for blood to flow, like a natural bypass around blocked arteries.
- EECP is a non-invasive, no pain, no side-effect treatment.
EECP is widely used in prevention, treatment and rehabilitation of cardiovascular diseases and other ischemic diseases.
It’s popular installed in rehabilitation centres, nursing home, fitness clubs, heart clinics and hospitals, and for home use.
Clinical benefit of EECP
ECG Amplifier: | Input impedance: >2MΩ Common-mode rejection ratio: >80dB Bandwidth: 1-20 Hz on display |
SpO2 Oxygen Saturation: | Oxygen saturation range: 0 to 100% Accuracy SpO2 (±1 Saturation Deviation) 60-100% ± 2 digits for adults using the Finger Clip Sensor 60-100% ± 3 digits for adults using Flex or Reflectance Sensor 60-100% ± 4 digits using Ear Clip Sensor |
Triggering Method: | External trigger: R-wave of patient ECG External trigger ratio: 1:1 or 1:2 ECG triggers range: 35-125 ± 1 bpm |
Filter Technique: | Low-pass digital filter eliminates 50/60Hz and high-frequency interference |
Treatment Pressure Range: | Adjust from 5-400 mmHg |
Cuffs: | 1 Set–Calves, lower thighs, and upper thigh/buttocks |
Treatment Session Time Setting: | Set treatment time from 5 to 120 minutes maximum. System automatically stop when set time expires. |
System Protection: | Three circuit breakers -Mains and Compressor, and an emergency stop button. Multiple auto-protections, fully guarantee treatment safety. |
Electrical Performance: | Power Requirements: 220V±22V AC, 50/60Hz, 1200VA |
System Dimension: | Dimension: 2000mm×800mm×700mm Net Weight: 220 kg |
Operating Environment: | Temperature 50 to 95℉ (10°C to 35°C ) Relative Humidity <80% (no condensation) Atmospheric Pressure 700 to 1060 hPa Atmospheric Free of corrosives gas |
Transport and Storage Environment: | Temperature -40 to 131℉ (-40 °C to 55°C) Relative Humidity <95% (no condensation) Atmospheric Pressure: 500 to 1060 hPa Atmospheric Free of corrosive gas |
About Us
Omay() Med Technologies Co.,Ltd is a manufacturer specialized in EECP production since 2008. Omay EECP machine designed by our engineer Dr.Zhou, student of Pro.Zheng zhen sheng(father of EECP machine in the world), during 1995~1998.
All producing process strictly follows the ISO9001 quality standards and our machine approved CE, ISO13485, CFDA.
Based on its advanced technology, competitive price and excellent backup service, Omay EECP machine selling very well both at home and at abroad.
Key Words: EECP machine, ECP machine, Enhanced External Counter Pulsation.
Qualification